2 Storeys with a Covered Upper Walkway
The reference shows 2 storeys, repeated room entrances and a railed upper walkway beneath a projecting canopy. View this configuration image. The room block can be discussed for offices or accommodation where each room opens toward an exterior circulation route. Decide the room schedule and service areas before choosing the total building length. The walkway must connect to the stair and landing arrangement, which the facade view does not fully establish. Door repetition alone does not determine bedroom count, occupancy or escape capacity.
Compare the Proposed Configuration with Published Supplier Modules
| Item | Longtai design reference | PQSE detachable module | GS Housing flat-pack module |
|---|---|---|---|
| Building system | Project-specific detachable configuration | Bolted detachable components | Flat-pack system |
| External dimensions, L × W × H | By approved project drawing | 5,950 × 3,000 × 2,800 mm | 6,055 × 2,990 or 2,435 × 2,896 mm |
| Opening or enclosure information | 2-storey room-block reference | 1 door and 2 windows in the reference model | 75 mm rock-wool wall panel with 0.5 mm steel faces |
| Configuration basis | LT-DG036; quotation and drawings required | Named supplier reference module | Named supplier flat-pack model |
Sources: PQSE detachable module specifications; GS Housing flat-pack specifications. These are supplier-published reference configurations with different systems and supply scopes. Their dimensions and materials are not assigned to this Longtai design and do not establish equivalent performance or completed-building cost.
Review the Walkway and Stair Layout for 2 Storeys
The 2-storey plan needs the walkway supports, clear passage, guarding and canopy connection reviewed with the modules. Submit intended room use, occupancy and site access so stairs and services can be located. Show roof and canopy drainage on the drawings. The quotation must identify walkway decking, stairs, railings, partitions and sanitary fit-out individually. The comparison modules below do not establish the overall length or supplied scope of this room block. Request a quotation for this configuration.
Frequently asked questions
How many accommodation rooms are included in this 2-storey container block?
The number is set by the project room schedule. The facade reference shows repeated entrances but does not establish a bedroom count, occupancy or complete floor plan.
Is the covered walkway included with the container room modules?
Walkway decking, canopy, railings and stairs must be listed in the quotation. They should not be assumed included in a standard module price.
Can the upper walkway connect to stairs at both ends of the building?
That arrangement can be reviewed against the site and access requirements. Stair locations, landings and structural connections must be confirmed on project drawings.