2 Cabin Levels with an External Stair
The reference shows 2 cabin levels, an exterior stair, an upper landing with railings and a canopy above the upper entrance. View this configuration image. The arrangement can be reviewed for separate activities on each level or for rooms that need direct exterior access. Define room use and occupancy before setting the stair position. The exterior stair needs space on the site plan beyond the cabin footprint. Its appearance does not establish riser dimensions, landing width or structural compliance, and the upper canopy must be coordinated with the entrance route.
Compare the Proposed Configuration with Published Supplier Modules
| Item | Longtai design reference | PQSE detachable module | GS Housing flat-pack module |
|---|---|---|---|
| Building system | Project-specific detachable configuration | Bolted detachable components | Flat-pack system |
| External dimensions, L × W × H | By approved project drawing | 5,950 × 3,000 × 2,800 mm | 6,055 × 2,990 or 2,435 × 2,896 mm |
| Opening or enclosure information | 2 cabin levels shown | 1 door and 2 windows in the reference model | 75 mm rock-wool wall panel with 0.5 mm steel faces |
| Configuration basis | LT-DG071; quotation and drawings required | Named supplier reference module | Named supplier flat-pack model |
Sources: PQSE detachable module specifications; GS Housing flat-pack specifications. These are supplier-published reference configurations with different systems and supply scopes. Their dimensions and materials are not assigned to this Longtai design and do not establish equivalent performance or completed-building cost.
Reserve Stair and Landing Space for 2 Levels
For the 2 levels, show the stair footprint, landings, guarding and supports on the site plan. Confirm the connection between the upper module and its supporting structure, together with the foundation arrangement. State which access components, canopy parts and interior services belong in the quotation. The total installed footprint includes more than the enclosed cabin plan; request dimensions for both the building and the access system before approving the order. Request a quotation for this configuration.
Frequently asked questions
Does the external stair increase the footprint of this two-level cabin?
Yes. The stair and landing require space beyond the enclosed cabin footprint. The project drawing must state their dimensions and location; no measurements are established by the reference.
Are the stair, landing and upper canopy included in the cabin quotation?
They must be individually identified in the quotation and drawings. The image establishes the intended arrangement, not the included access package or installation scope.
Can the external stair be placed on the other side of the two-level cabin?
A revised position can be reviewed with the module entrances, foundation and site access. Confirm the new connections and landing arrangement before ordering.