2 Storeys of Glazing and Opening Windows
The reference shows 2 storeys with a glazed facade and outward-opening window sections on the upper level. View this configuration image. The facade can be discussed for office rooms that need views from workspaces and meeting areas. Set the room partitions and desk positions before dividing the glazing into fixed and opening sections. Some rooms may need privacy or shading provisions. The image does not establish the glass build-up, opening area, structural supports or ventilation performance. Those values must be tied to the selected facade schedule.
Compare the Proposed Configuration with Published Supplier Modules
| Item | Longtai design reference | PQSE detachable module | GS Housing flat-pack module |
|---|---|---|---|
| Building system | Project-specific detachable configuration | Bolted detachable components | Flat-pack system |
| External dimensions, L × W × H | By approved project drawing | 5,950 × 3,000 × 2,800 mm | 6,055 × 2,990 or 2,435 × 2,896 mm |
| Opening or enclosure information | 2-storey glazed facade shown | 1 door and 2 windows in the reference model | 75 mm rock-wool wall panel with 0.5 mm steel faces |
| Configuration basis | LT-DG026; quotation and drawings required | Named supplier reference module | Named supplier flat-pack model |
Sources: PQSE detachable module specifications; GS Housing flat-pack specifications. These are supplier-published reference configurations with different systems and supply scopes. Their dimensions and materials are not assigned to this Longtai design and do not establish equivalent performance or completed-building cost.
Coordinate the Glazing and Access Across 2 Floors
For the 2-storey office proposal, request floor plans, elevations and access details that use the same module layout. Confirm the glass specification, window operation, shading and water-sealing details. Stairs, landings and fire or other project requirements need review for the destination. Include electrical loads, cooling provisions and meeting-room needs in the inquiry. The supplier module dimensions below are comparison references and do not set the finished building dimensions. Request a quotation for this configuration.
Frequently asked questions
What glass specification is used in the 2-storey container office facade?
The design reference does not establish a glass specification. The project glazing schedule must identify glass build-up, frames, opening sections and the required supporting details.
Can office partitions meet the glazed facade at different positions?
Partition positions should be coordinated with glazing mullions and the structural layout. Provide the room schedule before selecting facade divisions and service routes.
Does the glazed container office include air conditioning and stairs?
Cooling equipment, electrical work and stairs are project quotation items. The facade image does not define the supplied access or services package.